← Aellic Evidenz
Pulse Rate Measurement During Sleep Using Wearable Sensors, and its Correlation with the Menstrual Cycle Phases, A Prospective Observational Study
Shilaih, Clerck, Falco, Kübler, Leeners · 2017 · Scientific Reports 7(1):1294
What this work gives Aellic
274 cycles: pulse rate during sleep rises mid-luteally by +3.8 bpm compared with menstruation. One of three independent data sets behind the range of +2 to +4 bpm (the others: goodale2019 +3.96, jasinski2024 ~3.5 peak-to-trough). Aellic sets the cold start to +2.0 — the lower edge.
Where this sits in the engine
1 declared site: constants and thresholds in the code that point at this entry.
- Cycle Phases and cycle-aware baselines 1 site
Also in Cycle
- 2026 The diagnostic accuracy of wearable digital technology in detecting fertility window and menstrual cycles: a systematic review and Bayesian network meta-analysis
- 2020 The Effects of Menstrual Cycle Phase on Exercise Performance in Eumenorrheic Women: A Systematic Review and Meta-Analysis
- 2019 A Systematic Review and Meta-Analysis of Within-Person Changes in Cardiac Vagal Activity across the Menstrual Cycle: Implications for Female Health and Future Studies